| Description |
Model |
| |
FIT-300-N, FIT-300-EN,
FIT-300-D |
FIT-300-ASTM |
FIT-14 |
FIT-4.2 |
| |
CHARPY |
IZOD |
CHARPY |
IZOD |
IZOD |
| Pendulum Drop Angle (Degree) |
140 |
90 |
140 |
120 |
120 |
| Pendulum Effective Weight (Kg) |
21.300 |
21.300 |
22.350 |
4.665 |
1.40 |
| Striking velocity of Pendulm (m/Sec) |
5.308 |
3.994 |
5.18 |
2.44 |
2.45 |
| Pendulum Impact Energy (Joules) |
300 |
170 |
300 |
14 |
4.2 |
| Min. Scale Graduation (Joules) |
2 |
2 |
2 |
0.1 |
0.05 |
| (only for FIT-300-D) |
0.5 |
0.5 |
--- |
--- |
--- |
| Distance between axis of |
|
|
|
|
|
| pendulum to centre of strike |
813.5 |
813.5 |
775 |
204 |
204 |
| ~Length of pendulum in mm) |
|
|
|
|
|
| Max. total friction & windage losses |
0.5% of Max. Impact Energy |
0.5% of Max Impact Energy |
0.75% of Max Impact Energy |
0.5% of Max. Impact Energy |
0.5% of Max. Impact Energy |
| Srtiking edge |
| a. Angle (Degree) |
30 |
75 |
30 |
--- |
--- |
| b. Radius of curvature (mm) |
2 |
0.7 |
8 |
3.2 |
3.2 |
| c. Width at tip (mm) |
18 |
--- |
4 |
--- |
--- |
| d. Horizontal relief (Degree) |
--- |
10 |
--- |
--- |
--- |
| e. Vertical relief (Degree) |
--- |
5 |
--- |
--- |
--- |
| Specimen Anvils and supports |
| a. Suitable for max. |
|
|
|
|
|
| specimen cross section (mm) |
10 x 10 |
10 x 10 |
10 x 10 |
12.7 x 12.7 |
12.7 x 2.7 |
| b. Distance between |
|
|
|
|
|
| specimen Anvils (mm) |
40 |
--- |
40 |
--- |
--- |
| c Included angle of Anvil tip (Degree) |
79 |
--- |
80 |
--- |
--- |
| d. Radius of curvature at |
|
|
|
|
|
| Anvil tip. (mm) |
1 |
--- |
1 |
--- |
--- |
| Overall size (mm) (approx) |
760 (L) x440 (W) x 1925 (H) |
935(L) x 430 (W) x 2070 (H) |
500 (L) x 250 (W) x 625 (H) |
| Net Weight (kg) (approx) |
For Model FIT-300-N 300 For Model FIT-300-EN 450
For Model FIT-300-D 450 |
500 |
45 |
45 |